FAST DUO 60 kW / 80 kW / 120 kW / 160 kW / 200 kW

Introduction #

This document presents the specifications of the FAST DUO 60 kW, 80 kW, 120 kW, 160 kW and 200 kW stations (WB-DC-60D / WB-DC-80D / WB-DC-120D / WB-DC-160D / WB-DC-200D) and explains how to install and set up your station.

To help you better understand and use this product, the User’s Manual provides a detailed introduction to the functions, installation, operation and maintenance of the FAST DUO station. This manual is indispensable when installing, monitoring, debugging and maintaining the station.

Product presentation #

  1. WiFi/4G antenna
  2. Hot air outlet grille
  3. Rear door lock
  4. Output B
  5. Status indicators
  6. LCD touch screen
  7. RFID reader
  8. Emergency stop button
  9. Output A
  10. Front door latch
  11. Cold air inlet grille

Packing list #

ItemsQty.
1EV station1
2Link to user manual1
3Quality certificate1
5RFID card3
6Expansion dowel with hexagonal head M8*80/304 stainless steel9

Installation and wiring #

Floor installation #

  1. Keep a minimum clearance of 1.2 m around the station.
  1. The station must be installed on a customized concrete foundation.
  • The foundation pile must be compacted. In soft, damp soil, the foundation must be reinforced. The foundation should rest on the highest point in the area to avoid flooding.
  • The foundation pile must be made of reinforced concrete, requiring a minimum admissible bearing pressure of 1000 kg / square meter for the base.
  • Construct the main grounding busbar (busbar) and electrode according to substation grounding regulations. The grounding resistance must be less than 4Ω, a flat galvanized steel 50 x 4 is suggested.
  • The cable conduit uses 90 mm diameter PVC, the direction must be determined according to the situation on site, while the quantity depends on the number of HV / LV cables that will be used (use a redundant design).
  • A level bar should be used to level the foundation.
  • The internal foundation level should slope slightly towards the water collection pit.
  • The illustration is for reference only.
  1. The minimum height of the foundation is 150 mm above ground level, and the vertical inclination must be less than 5%.
  1. First remove the plates at the front and rear of the station.
  1. Slide the forklift blades into the opening under the bollard, above the transport pallet. Raise the bollard and loosen the bolts holding the pallet, then remove the pallet.
  1. Align the station on top of the concrete slab, taking care to center it and leave a gap of at least 1.2m on all four sides of the station.
  1. Before lowering the station, make sure the cables coming from the concrete pad are accessible.
  1. Once the station has been placed on the base, use the fixing holes as a guide to drill the concrete block. Clean the holes, if possible with a vacuum cleaner, to ensure that they are not obstructed by dust or debris. Then insert the expansion plugs to secure the station to the concrete stud. The station is now ready for wiring.

Wiring #

  1. Connect the three-phase, four-wire AC cables underground to the charger’s input terminal, respecting the color order and phase sequence. The earth cable must be connected to the charger’s earth bar. The wiring is illustrated below:
  1. Connect the charger’s earthing bar to the equipotential bonding bar at the installation site. The grounding cable must not be smaller than 25 mm². Grounding resistance must be less than 4Ω.
Power output L1 L2 L3 N PE
Terminal 60kW Red Black Grey Blue Yellow & Green
Cable 60kW ≥35mm²
≥AWG2
≥35mm²
≥AWG2
≥35mm²
≥AWG2
≥35mm²
≥AWG2
≥35mm²
≥AWG2

Parameter settings #

Once installation and wiring are complete, connect the charger to a computer and configure the parameters via the computer’s web browser.
The charger is ready for use by default, but it is recommended that you put it online (remote diagnostics, change of charging mode, charging reports, etc.).

Setting via the WB Charge application #

To access your bollard’s parameters with the WB Charge application, please refer to our WB Charge Application page, in the “Setting Wellborne Product Parameters” chapter.

Setup via your computer #

To access your terminal settings with your PC (Windows 10 & 11) or Mac, please refer to our Technical Brochure page, chapter “Setting Wellborne product parameters via a computer“.

The different charging modes of your station #

There are three operating modes for your Wellborne charging station: APP, RFID and Plug & Charge.

APP mode (third-party system operation: APP/RFID) #

With the WB Charge application, you can start or stop a charge, manage authorized users and tariffs, etc. For more information on how the WB Charge application works, please refer to the WB Charge application.

RFID mode #

In RFID mode, charging can only be initiated by swiping an RFID card over the terminal’s reader.
For more information on how to set up your reader/configurator and RFID cards, please refer to our Technical Brochure, chapter “RFID Card Configurator“.

Plug & Charge mode #

Plug & Charge mode allows you to start charging a vehicle as soon as it is connected to your charging station. If you wish to interrupt charging, simply press the on/off button above the T2 socket.

Anomalies #

Troubleshooting #

In the event of a fault, users can check the fault information on the LCD screen. Each fault is indicated by a number displayed on the LCD. If several faults occur at the same time, each number is displayed in chronological order at 3-second intervals. To find out more about diagnosing faults on your terminal, please refer to the “DC Fault Diagnostics” page.

Dynamic energy control & solar management #

For dynamic energy control and solar management of your bollard via the application, PC or Mac, please refer to our page “Setting Wellborne product parameters via the WB Charge application“, or “Accessing Wellborne product parameters via a computer“.

Technical specifications #

SPECIFICATIONSWB-DC-60D
IN & OUT
Input voltage260~530V AC
Nominal input voltage400V AC
Input frequency50 / 60Hz
DC output voltage150~1000V
Max. input current 95A
Power module referenceUR100040-SW 40kW 1000V/max80A
Max. output power 60kW
Max. output current 150A
Max. Output current / gun 150A
Voltage accuracy (DC)<±0.5%
Current accuracy (DC)≤±1% (at 20% ~ 100% of rated power)
Voltage regulation accuracy≤±0.5%
Current regulation accuracy≤±1%
Ripple coefficient (DC)RMS: ≤±0.5%; Peak: ≤±1%
Measurement accuracy0.5%
Efficiency≥95.2%
Charging interface typeCCS Type 2 (standard)
ConnectionPistol
Cable length5m
Number of charging points2
PROTECTION
Overvoltage protectionYes
Protection against undervoltageYes
Overload protectionYes
Short-circuit protectionYes
Earth leakage protectionYes
Overheating protectionYes
Lightning protectionYes
FUNCTIONS & ACCESSORIES
Ethernet / WIFI / 4GYes / Yes / Opt
LCD7-inch touch screen
RCDDELIXI CDM6LI-125L / 125A
Access controlRFID / QR / APP
LED indicatorYes
Emergency stop buttonYes
Pro-earthYes
MID meteringOpt
InstallationFloor-mounted
WORKING ENVIRONMENT
Protection classIP54
Shock resistanceIK10
Operating temperature-25°C ~+50°C
Relative humidity%-95% non-condensing
Maximum altitude<2000 m
CoolingForced air cooling
Standby power consumption<80W
Noise emission≤65db
MECHANICS
Dimension (W / H / D)600 / 1883 / 743mm
Weight (kg)247 kg
Packaging dimensions (W / H / D)860 / 2050 / 1060 mm
CERTIFICATIONS
CertificateCE

SPECIFICATIONSWB-DC-80D
IN & OUT
Input voltage260~530V AC
Nominal input voltage400V AC
Input frequency50 / 60Hz
DC output voltage150~1000V
Max. input current 125A
Power module referenceUR100040-SW 40kW 1000V/max80A
Max. output power 80kW
Max. output current 200A
Max. Output current / gun 200A
Voltage accuracy (DC)<±0.5%
Current accuracy (DC)≤±1% (at 20% ~ 100% of rated power)
Voltage regulation accuracy≤±0.5%
Current regulation accuracy≤±1%
Ripple coefficient (DC)RMS: ≤±0.5%; Peak: ≤±1%
Measurement accuracy0.5%
Efficiency≥95.2%
Charging interface typeCCS Type 2 (standard)
ConnectionPistol
Cable length5m
Number of charging points2
PROTECTION
Overvoltage protectionYes
Protection against undervoltageYes
Overload protectionYes
Short-circuit protectionYes
Earth leakage protectionYes
Overheating protectionYes
Lightning protectionYes
FUNCTIONS & ACCESSORIES
Ethernet / WIFI / 4GYes / Yes / Opt
LCD7-inch touch screen
RCDMCCB 3P+N 150A NXMLE-160S/3300
Access controlRFID / QR / APP
LED indicatorYes
Emergency stop buttonYes
Pro-earthYes
MID meteringOpt
InstallationFloor-mounted
WORKING ENVIRONMENT
Protection classIP54
Shock resistanceIK10
Operating temperature-25°C ~+50°C
Relative humidity%-95% non-condensing
Maximum altitude<2000 m
CoolingForced air cooling
Standby power consumption<100W
Noise emission≤65db
MECHANICS
Dimension (W / H / D)600 / 1883 / 743mm
Weight (kg)263 kg
Packaging dimensions (W / H / D)860 / 2050 / 1060 mm
CERTIFICATIONS
CertificateCE

SPECIFICATIONSWB-DC-120D
IN & OUT
Input voltage260~530V AC
Nominal input voltage400V AC
Input frequency50 / 60Hz
DC output voltage150~1000V
Max. input current 185A
Power module reference UR100040-SW 40kW 1000V/max100A
Max. output power 120kW
Max. output current 300A
Max. Output current / gun 200A
Voltage accuracy (DC)<±0.5%
Current accuracy (DC)≤±1% (at 20% ~ 100% of rated power)
Voltage regulation accuracy≤±0.5%
Current regulation accuracy≤±1%
Ripple coefficient (DC)RMS: ≤±0.5%; Peak: ≤±1%
Measurement accuracy0.5%
Efficiency≥95.2%
Charging interface typeCCS Type 2 (standard)
ConnectionPistol
Cable length5m
Number of charging points2
PROTECTION
Overvoltage protectionYes
Protection against undervoltageYes
Overload protectionYes
Short-circuit protectionYes
Earth leakage protectionYes
Overheating protectionYes
Lightning protectionYes
FUNCTIONS & ACCESSORIES
Ethernet / WIFI / 4GYes / Yes / Opt
LCD7-inch touch screen
RCDMCCB 3P+N 225A NXMLE-250S/3300
Access controlRFID / QR / APP
LED indicatorYes
Emergency stop buttonYes
Pro-earthYes
MID meteringOpt
InstallationFloor-mounted
WORKING ENVIRONMENT
Protection classIP54
Shock resistanceIK10
Operating temperature-25°C ~+50°C
Relative humidity%-95% non-condensing
Maximum altitude<2000 m
CoolingForced air cooling
Standby power consumption<120W
Noise emission≤65db
MECHANICS
Dimension (W / H / D)600 / 1883 / 743mm
Weight (kg)279 kg
Packaging dimensions (W / H / D)860 / 2050 / 1060 mm
CERTIFICATIONS
CertificateCE

SPECIFICATIONSWB-DC-160D
IN & OUT
Input voltage260~530V AC
Nominal input voltage400V AC
Input frequency50 / 60Hz
DC output voltage150~1000V
Max. input current 245A
Power module referenceUR100040-SW 40kW 1000V/max80A
Max. output power 160kW
Max. output current 400A
Max. Output current / gun 200A
Voltage accuracy (DC)<±0.5%
Current accuracy (DC)≤±1% (at 20% ~ 100% of rated power)
Voltage regulation accuracy≤±0.5%
Current regulation accuracy≤±1%
Ripple coefficient (DC)RMS: ≤±0.5%; Peak: ≤±1%
Measurement accuracy0.5%
Efficiency≥95.2%
Charging interface typeCCS Type 2 (standard)
ConnectionPistol
Cable length5m
Number of charging points2
PROTECTION
Overvoltage protectionYes
Protection against undervoltageYes
Overload protectionYes
Short-circuit protectionYes
Earth leakage protectionYes
Overheating protectionYes
Lightning protectionYes
FUNCTIONS & ACCESSORIES
Ethernet / WIFI / 4GYes / Yes / Opt
LCD7-inch touch screen
RCDMCCB 3P+N 315A NXMLE-400S/3300
Access controlRFID / QR / APP
LED indicatorYes
Emergency stop buttonYes
Pro-earthYes
MID meteringOpt
InstallationFloor-mounted
WORKING ENVIRONMENT
Protection classIP54
Shock resistanceIK10
Operating temperature-25°C ~+50°C
Relative humidity%-95% non-condensing
Maximum altitude<2000 m
CoolingForced air cooling
Standby power consumption<120W
Noise emission≤65db
MECHANICS
Dimension (W / H / D)600 / 1883 / 743mm
Weight (kg)294 kg
Packaging dimensions (W / H / D)860 / 2050 / 1060 mm
CERTIFICATIONS
CertificateCE

SPECIFICATIONSWB-DC-200D
IN & OUT
Input voltage260~530V AC
Nominal input voltage400V AC
Input frequency50 / 60Hz
DC output voltage150~1000V
Max. input current 3055A
Power module referenceUR100040-SW 40kW 1000V/max100A
Max. output power 200kW
Max. output current 500A
Max. Output current / gun 200A
Voltage accuracy (DC)<±0.5%
Current accuracy (DC)≤±1% (at 20% ~ 100% of rated power)
Voltage regulation accuracy≤±0.5%
Current regulation accuracy≤±1%
Ripple coefficient (DC)RMS: ≤±0.5%; Peak: ≤±1%
Measurement accuracy0.5%
Efficiency≥95.2%
Charging interface typeCCS Type 2 (standard)
ConnectionPistol
Cable length5m
Number of charging points2
PROTECTION
Overvoltage protectionYes
Protection against undervoltageYes
Overload protectionYes
Short-circuit protectionYes
Earth leakage protectionYes
Overheating protectionYes
Lightning protectionYes
FUNCTIONS & ACCESSORIES
Ethernet / WIFI / 4GYes / Yes / Opt
LCD7-inch touch screen
RCDNXMLE-400S/3300 – MCCB 3P+N – 400A
Access controlRFID / QR / APP
LED indicatorYes
Emergency stop buttonYes
Pro-earthYes
MID meteringOpt
InstallationFloor-mounted
WORKING ENVIRONMENT
Protection classIP54
Shock resistanceIK10
Operating temperature-25°C ~+50°C
Relative humidity%-95% non-condensing
Maximum altitude<2000 m
CoolingForced air cooling
Standby power consumption<135W
Noise emission≤65db
MECHANICS
Dimension (W / H / D)600 / 1883 / 743mm
Weight (kg)310 kg
Packaging dimensions (W / H / D)860 / 2050 / 1060 mm
CERTIFICATIONS
CertificateCE

Appendices #

Installation diagrams for dynamic energy control #

List of compatible Wellborne accessories #

WB-RFID

RFID card reader/configurator

WB-RC

Pack of 10 RFID cards

WB-4G

4G module

WB-W

Wi-Fi module

WB-SIM4G

SIM card

What did you think of this article?
Updated on September 26, 2024

Contact us

Customer and Technical Support

Use our ticket submission form to report a problem or request technical support.