Energy management

Static energy control #

Static control simply sets an electrical power limit that must not be exceeded for a group of bollards. It applies to bollards connected and grouped via the charge.wellborne.co.ukplatform, and does not require the installation of any additional equipment.

Dynamic energy management #

Intelligent recharging works by modulating the power of the charging stations. Vehicle charging time is then smoothed out over longer time slots. This solution avoids exceeding the power allowed by the electricity meter, and reduces the power allocated to charging at peak consumption times to avoid saturating the network.

Dynamic energy management adapts the power demand to the power available in real time, and is applicable to non-grouped single terminal installations.

Single-phase power supply
Three-phase power supply

Red: Connections and accessories required when the terminal is located less than 10 meters from the low-voltage switchboard.

Blue: Connections and accessories required when the terminal is located more than 10 metres from the Low Voltage panel.

NB. 1 – The arrow on the cores must point towards the TGBT.

NB.1 – For the EASTRON SDM630MCT (v2), terminals 5 and 6 must be jumpered to supply power. Default address: 01.

Activate dynamic steering #

To activate dynamic steering, you need to use the WB Charge application.
For further details, please refer to the corresponding section: Dynamic control

Energy management equipment #

Dynamic energy control of a home terminal with the WB-1MCT.

Load shedding / solar energy - single-phase equipment #

Single-phase terminal or station (installed within 10m of the TGBT) #

Single-phase terminal or station (installed more than 10m from the TGBT) #

Load shedding / solar energy - three-phase equipment #

Three-phase terminal or station (installed less than 10m from the TGBT) #

Three-phase terminal or station (installed more than 10m from the TGBT) #

Dynamic terminal cluster control with WB-LMS #

The WB-LMS is equipped with an Enerlog controller that establishes communication between the charge points, the meter and the power source. It enables dynamic energy control of all charge points, as well as management operations for each connected charge point.

The cluster of terminals connected to the WB-LMS can be supervised on the platform charge.wellborne.co.uk

Power supply #

Signal #

Communication - Parallel
Communication - series
What did you think of this article?