ULTRA DUO 180 kW / 240 kW / 280 kW / 320 kW / 360 kW / 400 kW / 480 kW

Introduction #

This document presents the specifications of the ULTRA DUO 180 KW / 240 kW / 280 kW / 320 kW / 360 kW / 400 kW / 480 kW stations (WB-DC-240D, WB-DC-280D, WB-DC-320D, WB-DC-360D, WB-DC-400D and WB-DC-480D) and explains how to install and set up your station.

To help you better understand and use this product, the User’s Manual provides a detailed introduction to the functions, installation, operation and maintenance of the ULTRA DUO station. This manual is indispensable when installing, monitoring, debugging and maintaining the station.

We sincerely hope that this product will meet your needs, so please do not hesitate to send us your comments and suggestions on the performance and functions of our products. We are constantly improving the quality of our products and services.

Product presentation #

  1. Hot air outlet grilles
  2. Outputs A and B
  3. Rear door lock
  4. Backlit logo
  5. LCD touch screen
  6. RFID reader
  7. Emergency stop button
  8. Front door latch
  9. Cold air inlet grille

Installation and wiring #

Floor installation #

  1. Keep a minimum clearance of 1.2 m around the station.
  1. The station must be installed on a customized concrete foundation.
  • The foundation pile must be compacted. In soft, damp soil, the foundation must be reinforced. The foundation should rest on the highest point in the area to avoid flooding.
  • The foundation pile must be made of reinforced concrete, requiring a minimum admissible bearing pressure of 1000 kg / square meter for the base.
  • Construct the main grounding busbar (busbar) and electrode according to substation grounding regulations. The grounding resistance must be less than 4Ω, a flat galvanized steel 50 x 4 is suggested.
  • The cable conduit uses 90 mm diameter PVC, the direction must be determined according to the situation on site, while the quantity depends on the number of HV / LV cables that will be used (use a redundant design).
  • A level bar should be used to level the foundation.
  • The internal foundation level should slope slightly towards the water collection pit.
  • The illustration is for reference only.
  1. The minimum height of the foundation is 150 mm above ground level, and the vertical inclination must be less than 5%.
  1. The minimum height of the foundation is 150 mm above ground level, and the vertical inclination must be less than 5%.
  1. Slide the forklift blades into the opening under the bollard, above the transport pallet. Raise the bollard and loosen the bolts holding the pallet, then remove the pallet.
  1. Align the station on top of the concrete slab, taking care to center it and leave a gap of at least 1.2m on all four sides of the station.
  1. Before lowering the station, make sure the cables coming from the concrete pad are accessible.
  1. Once the station has been placed on the base, use the fixing holes as a guide to drill the concrete block. Clean the holes, if possible with a vacuum cleaner, to ensure that they are not obstructed by dust or debris. Then insert the expansion plugs to secure the station to the concrete stud. The station is now ready for wiring.

Technical specifications #

SPECIFICATIONSWB-DC-180D
IN & OUT
Input voltage340~460V AC
Nominal input voltage400V AC
Input frequency50 / 60Hz
DC output voltage200~900V
Max. input current 365A
Power module referenceUR100040-SW-40KW 1000V/max100A
Max. output power 180kW
Max. output current 200A
Max. Output current / gun 200A
Charging interface typeCCS Type 2 (standard)
ConnectionPistol
Cable length5m
Number of charging points2
PROTECTION
Overvoltage protectionYes
Protection against undervoltageYes
Overload protectionYes
Short-circuit protectionYes
Earth leakage protectionYes
Overheating protectionYes
Lightning protectionYes
FUNCTIONS & ACCESSORIES
Ethernet / WIFI / 4GYes / Yes / Opt
LCD7-inch touch screen
RCDCHNT NXMLE-400S/3300 – 315A
Access controlRFID / QR / APP
LED indicatorYes
Emergency stop buttonYes
Pro-earthYes
MID meteringOpt
InstallationFloor-mounted
WORKING ENVIRONMENT
Protection classIP54
Shock resistanceIK10
Operating temperature-25°C ~+55°C
Relative humidity%-95% non-condensing
Maximum altitude<2000 m
CoolingForced air cooling
Standby power consumption<80W
Noise emission≤65db
MECHANICS
Dimension (W / H / D)1190 / 2200 / 1000mm
Weight (kg)625 kg
CERTIFICATIONS
CertificateCE
SPECIFICATIONSWB-DC-240D
IN & OUT
Input voltage340~460V AC
Nominal input voltage400V AC
Input frequency50 / 60Hz
DC output voltage150~1000V
Max. input current 365A
Power module referenceUR100040-SW-40KW 1000V/max100A
Max. output power 240kW
Max. output current 400A
Max. Output current / gun 200A
Charging interface typeCCS Type 2 (standard)
ConnectionPistol
Cable length5m
Number of charging points2
PROTECTION
Overvoltage protectionYes
Protection against undervoltageYes
Overload protectionYes
Short-circuit protectionYes
Earth leakage protectionYes
Overheating protectionYes
Lightning protectionYes
FUNCTIONS & ACCESSORIES
Ethernet / WIFI / 4GYes / Yes / Opt
LCD7-inch touch screen
RCDNXMLE-630S/3300 – 500A
Access controlRFID / QR / APP
LED indicatorYes
Emergency stop buttonYes
Pro-earthYes
MID meteringOpt
InstallationFloor-mounted
WORKING ENVIRONMENT
Protection classIP54
Shock resistanceIK10
Operating temperature-25°C ~+55°C
Relative humidity%-95% non-condensing
Maximum altitude<2000 m
CoolingForced air cooling
Standby power consumption<100W
Noise emission≤65db
MECHANICS
Dimensions (W / H / D)1750 / 2100 / 1372 mm
Weight (kg)625 kg
CERTIFICATIONS
CertificateCE
SPECIFICATIONSWB-DC-280D
IN & OUT
Input voltage340~460V AC
Nominal input voltage400V AC
Input frequency50 / 60Hz
DC output voltage150~1000V
Max. input current 425A
Power module referenceUR100040-SW-40KW 1000V/max100A
Max. output power 280kW
Max. output current 400A
Max. Output current / gun 200A
Charging interface typeCCS Type 2 (standard)
ConnectionPistol
Cable length5m
Number of charging points2
PROTECTION
Overvoltage protectionYes
Protection against undervoltageYes
Overload protectionYes
Short-circuit protectionYes
Earth leakage protectionYes
Overheating protectionYes
Lightning protectionYes
FUNCTIONS & ACCESSORIES
Ethernet / WIFI / 4GYes / Yes / Opt
LCD7-inch touch screen
RCDNXMLB-630S/3300 – 630A
Access controlRFID / QR / APP
LED indicatorYes
Emergency stop buttonYes
Pro-earthYes
MID meteringOpt
InstallationFloor-mounted
WORKING ENVIRONMENT
Protection classIP54
Shock resistanceIK10
Operating temperature-25°C ~+55°C
Relative humidity%-95% non-condensing
Maximum altitude<2000 m
CoolingForced air cooling
Standby power consumption<120W
Noise emission≤65db
MECHANICS
Dimensions (W / H / D)1750 / 2100 / 1372 mm
Weight (kg)640 kg
CERTIFICATIONS
CertificateCE
SPECIFICATIONSWB-DC-320D
IN & OUT
Input voltage340~460V AC
Nominal input voltage400V AC
Input frequency50 / 60Hz
DC output voltage150~1000V
Max. input current 486A
Power module referenceUR100040-SW-40KW 1000V/max100A
Max. output power 320kW
Max. output current 400A
Max. Output current / gun 200A
Charging interface typeCCS Type 2 (standard)
ConnectionPistol
Cable length5m
Number of charging points2
PROTECTION
Overvoltage protectionYes
Protection against undervoltageYes
Overload protectionYes
Short-circuit protectionYes
Earth leakage protectionYes
Overheating protectionYes
Lightning protectionYes
FUNCTIONS & ACCESSORIES
Ethernet / WIFI / 4GYes / Yes / Opt
LCD7-inch touch screen
RCDNXMLB-630S/3300 – 630A
Access controlRFID / QR / APP
LED indicatorYes
Emergency stop buttonYes
Pro-earthYes
MID meteringOpt
InstallationFloor-mounted
WORKING ENVIRONMENT
Protection classIP54
Shock resistanceIK10
Operating temperature-25°C ~+55°C
Relative humidity%-95% non-condensing
Maximum altitude<2000 m
CoolingForced air cooling
Standby power consumption<140W
Noise emission≤65db
MECHANICS
Dimensions1750 / 2100 / 1372 mm
Weight (kg)655 kg
CERTIFICATIONS
CertificateCE
SPECIFICATIONSWB-DC-360D
IN & OUT
Input voltage340~460V AC
Nominal input voltage400V AC
Input frequency50 / 60Hz
DC output voltage150~1000V
Max. input current 547A
Power module referenceUR100040-SW-40KW 1000V/max100A
Max. output power 360kW
Max. output current 400A
Max. Output current / gun 200A
Charging interface typeCCS Type 2 (standard)
ConnectionPistol
Cable length5m
Number of charging points2
PROTECTION
Overvoltage protectionYes
Protection against undervoltageYes
Overload protectionYes
Short-circuit protectionYes
Earth leakage protectionYes
Overheating protectionYes
Lightning protectionYes
FUNCTIONS & ACCESSORIES
Ethernet / WIFI / 4GYes / Yes / Opt
LCD7-inch touch screen
RCDNXMLB-630S/3300 – 700A
Access controlRFID / QR / APP
LED indicatorYes
Emergency stop buttonYes
Pro-earthYes
MID meteringOpt
InstallationFloor-mounted
WORKING ENVIRONMENT
Protection classIP54
Shock resistanceIK10
Operating temperature-25°C ~+55°C
Relative humidity%-95% non-condensing
Maximum altitude<2000 m
CoolingForced air cooling
Standby power consumption<160W
Noise emission≤65db
MECHANICS
Dimensions (W / H / D)1750 / 2100 / 1372 mm
Weight (kg)670 kg
CERTIFICATIONS
CertificateCE
SPECIFICATIONSWB-DC-400D
IN & OUT
Input voltage340~460V AC
Nominal input voltage400V AC
Input frequency50 / 60Hz
DC output voltage150~1000V
Max. input current 600A
Power module referenceUR100040-SW-40KW 1000V/max100A
Max. output power 400kW
Max. output current Peak 700A (10 min) – 400A
Max. Output current / gun Peak 350A (10 min) – 300A
Charging interface typeCCS Type 2 (standard)
ConnectionPistol
Cable length5m
Number of charging points2
PROTECTION
Overvoltage protectionYes
Protection against undervoltageYes
Overload protectionYes
Short-circuit protectionYes
Earth leakage protectionYes
Overheating protectionYes
Lightning protectionYes
FUNCTIONS & ACCESSORIES
Ethernet / WIFI / 4GYes / Yes / Opt
LCD7-inch touch screen
RCDMCCB + 750A circuit breakers (600A*1.25)
Access controlRFID / QR / APP
LED indicatorYes
Emergency stop buttonYes
Pro-earthYes
MID meteringOpt
InstallationFloor-mounted
WORKING ENVIRONMENT
Protection classIP54
Shock resistanceIK10
Operating temperature-25°C ~+55°C
Relative humidity%-95% non-condensing
Maximum altitude<2000 m
CoolingForced air cooling
Standby power consumption<150W
Noise emission≤65db
MECHANICS
Dimensions (W / H / D)1750 / 2100 / 1372 mm
Weight (kg)700 kg
CERTIFICATIONS
CertificateCE
SPECIFICATIONSWB-DC-480D
IN & OUT
Input voltage340~460V AC
Nominal input voltage400V AC
Input frequency50 / 60Hz
DC output voltage150~1000V
Max. input current 720A
Power module referenceUR100040-SW-40KW 1000V/max100A
Max. output power 480kW
Max. output current Peak 700A (10min) – 400A
Max. Output current / gun Peak 350A (10 min) – 300A
Charging interface typeCCS Type 2 (standard)
ConnectionPistol
Cable length5m
Number of charging points2
PROTECTION
Overvoltage protectionYes
Protection against undervoltageYes
Overload protectionYes
Short-circuit protectionYes
Earth leakage protectionYes
Overheating protectionYes
Lightning protectionYes
FUNCTIONS & ACCESSORIES
Ethernet / WIFI / 4GYes / Yes / Opt
LCD7-inch touch screen
RCDMCCB + circuit breakers 900A (720A*1.25)
Access controlRFID / QR / APP
LED indicatorYes
Emergency stop buttonYes
Pro-earthYes
MID meteringOpt
InstallationFloor-mounted
WORKING ENVIRONMENT
Protection classIP54
Shock resistanceIK10
Operating temperature-25°C ~+55°C
Relative humidity%-95% non-condensing
Maximum altitude<2000 m
CoolingForced air cooling
Standby power consumption<30W
Noise emission≤65db
MECHANICS
Dimensions (W / H / D)1750 / 2100 / 1372 mm
Weight (kg)732 kg
CERTIFICATIONS
CertificateCE
What did you think of this article?
Updated on September 26, 2024